40-Channel DWDM Gaussian, 1RU Rackmount


Overview

The 40-channel DWDM Mux/Demux filter provides a solid capacity solution for modern fiber networks.  This Rackmount filter uses ITU standard wavelengths that align with industry fixed and tunable transceivers. Utilizing 1 rack unit (1RU), and 100GHz channel spacing, this rack mounted filter provides a very economical capacity solution. The 40-channel Mux/Demux utilizes low loss and reliable Gaussian filters to help increase the optical power budget of your fiber network.

DWDM capacity solutions are passive and require no power, or configuration. DWDM filters are used to allow the combination (Multiplexing) and separation (Demultiplexing) of multiple wavelengths over single mode fiber and provide a high quality, low loss, fiber capacity solution.

Plugin Optics 40-Channel DWDM solutions support controlled environment deployments. Placing these filters allow you to deploy new high data rate circuits or recover existing fiber along a route, reducing or eliminating the need for new fiber builds all together.

Features

  • Capacity Gain: 40 to 1
  • Monitor Port: 2%
  • 40 ITU Channels
  • Low Loss Gaussian Filter
  • Technology: DWDM
  • Configuration: Mux/Demux
  • Form Factor: 1 Rack Unit

Topologies

  • Point to Point
  • Linear Chain
  • Collapsed/Diverse Ring

Deployment

  • Central Office, Head End, Data Center, MDU
TECHNICAL SPECS
ParameterUnitSpecification
NUMBER OF CHANNELSCH40ch DWDM
OPERATING WAVELENGTHnm1260-1620
DWDM CHANNEL SPACINGGHz100
PASSBAND: MON PORTnm1260-1570
PASSBAND: DWDM CHANNELSnmITU ± .11
INSERTION LOSSdB<4.0
ORDERING IFORMATION
VIEW ORDERING INFO
Part NumberDescription
PLO-11DG-AAAA-LC1RU, 19-23 Inch, 40 Channel DWDM Mux-Demux, Gaussian, ITU CH 20-59, 1561.42 - 1530.33, 2% Monitor, LC-UPC

8-Channel DWDM +1310nm MUX/DMX, LGX


Overview

The 8-channel DWDM + 1310nm filter and Expansion port provides a solid capacity solution for modern fiber networks. This LGX module combines 8 ITU standard DWDM wavelengths and a wideband 1310nm port to allow the overlay of legacy 1310nm circuits or the next evolution of 100G circuits. The included Expansion port provides additional growth up to 40 DWDM channels without interrupting the initially deployed circuits.

DWDM capacity solutions are passive and require no power, or configuration. DWDM filters are used to allow the combination (Multiplexing) and separation (Demultiplexing) of multiple wavelengths over single mode fiber and provide a high quality, low loss, fiber capacity solution.

Plugin Optics LGX mounting solutions support controlled environment and I-Temp deployments.

Features

  • 8 Channel DWDM
  • Configuration: Mux/Dmx
  • 5 Variants: ITU Ch 20-59
  • 2% Monitor Port
  • Form Factor: LGX
  • Temp Range: I-Temp

Topologies

  • Central Office
  • Headend
  • Remote Site
  • Cabinet
  • Pedestal

Deployment

  • Point to Point
  • Linear Chain
  • Collapsed/Diverse Ring
TECHNICAL SPECS
ParameterUnitSpecification
NUMBER OF CHANNELSCH8 DWDM, +1310nm, EXPANSION PORT
OPERATING WAVELENGTHnm1260-1360, 1520-1570
DWDM CHANNEL SPACINGGHz100
PASSBAND: 1310NM PORTnm1260-1360
PASSBAND: EXPANSION PORTnm1520-1570
PASSBAND: DWDM CHANNELSnmITU ± .11
INSERTION LOSSdB1310nm < 1.4, EXP< 3.2, COM-DWDM <3.4
ORDERING IFORMATION
VIEW ORDERING INFO
Part NumberDescription
PLO-L2DT-B9C1-LCLGX, 8 CHANNEL DWDM +1310 +EXP, MUX-DEMUX, ITIU C21-C27, 1561.42 - 1555.75, 2% MONITOR, LC-UPC
PLO-L2DT-B9C2-LCLGX, 8 CHANNEL DWDM +1310 +EXP, MUX-DEMUX, ITU C28-C35, 1554.94 - 1549.32, 2% MONITOR, LC-UPC
PLO-L2DT-B9C3-LCLGX, 8 CHANNEL DWDM +1310 +EXP, MUX-DEMUX, ITU C36-C43, 1548.51 - 1542.94, 2% MONITOR, LC-UPC
PLO-L2DT-B9C4-LCLGX, 8 CHANNEL DWDM +1310 +EXP, MUX-DEMUX, ITU C44-51, 1542.14 - 1536.61, 2% MONITOR, LC-UPC
PLO-L2DT-B9C5-LCLGX, 8 CHANNEL DWDM +1310 +EXP, MUX-DEMUX, ITU C52-C59, 1535.82 - 1530.33, 2% MONITOR, LC-UPC

4-Channel DWDM OADM, LGX


Overview

DWDM Optical Add/Drop Multiplexers (OADM) allow for midspan access of DWDM channels along a single mode fiber route. 4-channel DWDM OADMs are commonly used at sites along a fiber route carrying 8 to 40+ DWDM channels and allow access to 4 channels while expressing the remaining channels through the site.

Plugin Optics DWDM OADM filter solutions are passive and require no power, or configuration. OADM filters are used to allow adding and dropping of DWDM wavelengths, West and East, along a single mode fiber route and provide a high quality, low loss, fiber capacity solution.

Plugin Optics LGX mounting solutions support controlled environment and I-Temp deployments.

Features

  • 4 Channel DWDM
  • Configuration: OADM
  • 10 Variants: ITU Ch 20-59
  • 2% Monitor Port
  • Form Factor: LGX
  • Temp Range: I-Temp

Topologies

  • Central Office
  • Headend
  • Remote Site
  • Cabinet
  • Pedestal

Deployment

  • Point to Point
  • Linear Chain
  • Collapsed/Diverse Ring
TECHNICAL SPECS
ParameterUnitSpecification
NUMBER OF CHANNELSCH4 DWDM, WEST & EAST
OPERATING WAVELENGTHnm1520-1570
DWDM CHANNEL SPACINGGHz100
PASSBAND: EXPRESSnm1520-1570
PASSBAND: DWDM CHANNELSnmITU ± .11
INSERTION LOSSdBEXP< 3.5, COM-DWDM <3.7
ORDERING IFORMATION
VIEW ORDERING INFO
Part NumberDescription
PLO-L3DT-A4D1-LCLGX, 4 CHANNEL DWDM OADM, ITU C20-C23, 1561.42, 1560.61, 1559.79, 1558.98, 2% MONITOR, LC-UPC
PLO-L3DT-A4D2-LCLGX, 4 CHANNEL DWDM OADM, ITU C24-C27, 1558.17, 1557.36, 1556.55, 1555.75, 2% MONITOR, LC-UPC
PLO-L3DT-A4D3-LCLGX, 4 CHANNEL DWDM OADM, ITU C28-C31, 1554.94, 1554.13, 1553.33, 1552.52, 2% MONITOR, LC-UPC
PLO-L3DT-A4D4-LCLGX, 4 CHANNEL DWDM OADM, ITU C32-C35, 1551.72, 1550.92, 1550.12, 1549.32, 2% MONITOR, LC-UPC
PLO-L3DT-A4D5-LCLGX, 4 CHANNEL DWDM OADM, ITU C36-C39, 1548.51, 1547.72, 1546.92, 1546.12, 2% MONITOR, LC-UPC
PLO-L3DT-A4D6-LCLGX, 4 CHANNEL DWDM OADM, ITU C40-C43, 1545.32, 1544.53, 1543.73, 1542.94, 2% MONITOR, LC-UPC
PLO-L3DT-A4D7-LCLGX, 4 CHANNEL DWDM OADM, ITU C44-C47, 1542.14, 1541.35, 1540.56, 1539.77, 2% MONITOR, LC-UPC
PLO-L3DT-A4D8-LCLGX, 4 CHANNEL DWDM OADM, ITU C48-C51, 1538.98, 1538.19, 1537.40, 1536.61, 2% MONITOR, LC-UPC
PLO-L3DT-A4D9-LCLGX, 4 CHANNEL DWDM OADM, ITU C52-C55, 1535.82, 1535.04, 1534.25, 1533.47, 2% MONITOR, LC-UPC
PLO-L3DT-A4D0-LCLGX, 4 CHANNEL DWDM OADM, ITU C56-C59, 1532.68, 1531.90, 1531.12, 1530.33, 2% MONITOR, LC-UPC

2-Channel DWDM OADM, LGX


Overview

DWDM Optical Add/Drop Multiplexers (OADM) allow for midspan access of DWDM channels along a single mode fiber route. 2-channel DWDM OADMs are commonly used at sites along a fiber route carrying 8 to 40+ DWDM channels and allow access to 2 channels while expressing the remaining channels through the site.

Plugin Optics DWDM OADM filter solutions are passive and require no power, or configuration. OADM filters are used to allow adding and dropping of DWDM wavelengths, West and East, along a single mode fiber route and provide a high quality, low loss, fiber capacity solution.

Plugin Optics LGX mounting solutions support controlled environment and I-Temp deployments.

Features

  • 2 Channel DWDM 
  • Configuration: OADM 
  • 20 Variants: ITU Ch 20-59 
  • 2% Monitor Port 
  • Form Factor: LGX 
  • Temp Range: I-Temp 

Topologies

  • Central Office 
  • Headend 
  • Remote Site 
  • Cabinet 
  • Pedestal 

Deployment

  • Point to Point
  • Linear Chain
  • Collapsed/Diverse Ring
TECHNICAL SPECS
ParameterUnitSpecification
NUMBER OF CHANNELSCH2 DWDM, WEST & EAST
OPERATING WAVELENGTHnm1520-1570
DWDM CHANNEL SPACINGGHz100
PASSBAND: EXPRESSnm1520-1570
PASSBAND: DWDM CHANNELSnmITU ± .11
INSERTION LOSSdBEXP< 2.2, COM-DWDM <1.9
ORDERING IFORMATION
VIEW ORDERING INFO
Part NumberDescription
PLO-L3DT-A2E1-LCLGX, 2 CHANNEL DWDM OADM, ITU C20-C21, 1561.42, 1560.61, 2% MONITOR, LC-UPC
PLO-L3DT-A2E2-LCLGX, 2 CHANNEL DWDM OADM, ITU C22-C23, 1559.79, 1558.98, 2% MONITOR, LC-UPC
PLO-L3DT-A2E3-LCLGX, 2 CHANNEL DWDM OADM, ITU C24-C25, 1558.17, 1557.36, 2% MONITOR, LC-UPC
PLO-L3DT-A2E4-LCLGX, 2 CHANNEL DWDM OADM, ITU C26-C27, 1556.55, 1555.75, 2% MONITOR, LC-UPC
PLO-L3DT-A2E5-LCLGX, 2 CHANNEL DWDM OADM, ITU C28-C39, 1554.94, 1554.13, 2% MONITOR, LC-UPC
PLO-L3DT-A2E6-LCLGX, 2 CHANNEL DWDM OADM, ITU C30-C31, 1553.33, 1552.52, 2% MONITOR, LC-UPC
PLO-L3DT-A2E7-LCLGX, 2 CHANNEL DWDM OADM, ITU C32-C33, 1551.72, 1550.92, 2% MONITOR, LC-UPC
PLO-L3DT-A2E8-LCLGX, 2 CHANNEL DWDM OADM, ITU C34-C35, 1550.12, 1549.32, 2% MONITOR, LC-UPC
PLO-L3DT-A2E9-LCLGX, 2 CHANNEL DWDM OADM, ITU C36-C37, 1548.51, 1547.72, 2% MONITOR, LC-UPC
PLO-L3DT-A2E0-LCLGX, 2 CHANNEL DWDM OADM, ITU C38-C39, 1546.92, 1546.12, 2% MONITOR, LC-UPC
PLO-L3DT-A2EA-LCLGX, 2 CHANNEL DWDM OADM, ITU C40-C41, 1545.32, 1544.53, 2% MONITOR, LC-UPC
PLO-L3DT-A2EB-LCLGX, 2 CHANNEL DWDM OADM, ITU C42-C43, 1543.73, 1542.94, 2% MONITOR, LC-UPC
PLO-L3DT-A2EC-LCLGX, 2 CHANNEL DWDM OADM, ITU C44-C45, 1542.14, 1541.35, 2% MONITOR, LC-UPC
PLO-L3DT-A2ED-LCLGX, 2 CHANNEL DWDM OADM, ITU C46-C47, 1540.56, 1539.77, 2% MONITOR, LC-UPC
PLO-L3DT-A2EE-LCLGX, 2 CHANNEL DWDM OADM, ITU C48-C49, 1538.98, 1538.19, 2% MONITOR, LC-UPC
PLO-L3DT-A2EF-LCLGX, 2 CHANNEL DWDM OADM, ITU C50-C51, 1537.40, 1536.61, 2% MONITOR, LC-UPC
PLO-L3DT-A2EG-LCLGX, 2 CHANNEL DWDM OADM, ITU C52-C53, 1535.82, 1535.04, 2% MONITOR, LC-UPC
PLO-L3DT-A2EH-LCLGX, 2 CHANNEL DWDM OADM, ITU C54-C55, 1534.25, 1533.47, 2% MONITOR, LC-UPC
PLO-L3DT-A2EJ-LCLGX, 2 CHANNEL DWDM OADM, ITU C56-C57, 1532.68, 1531.90, 2% MONITOR, LC-UPC
PLO-L3DT-A2EK-LCLGX, 2 CHANNEL DWDM OADM, ITU C58-C59, 1531.12, 1530.33, 2% MONITOR, LC-UPC

1-Channel DWDM OADM, LGX


Overview

DWDM Optical Add/Drop Multiplexers (OADM) allow for midspan access of DWDM channels along a single mode fiber route. 1-channel DWDM OADMs are commonly used at sites along a fiber route carrying 8 to 40+ DWDM channels and allow access to 1 channel while expressing the remaining channels through the site.

Plugin Optics DWDM OADM filter solutions are passive and require no power, or configuration. OADM filters are used to allow adding and dropping of DWDM wavelengths, West and East, along a single mode fiber route and provide a high quality, low loss, fiber capacity solution.

Plugin Optics LGX mounting solutions support controlled environment and I-Temp deployments.

Features

  • 1 Channel DWDM 
  • Configuration: OADM 
  • 40 Variants: ITU Ch 20-59 
  • 2% Monitor Port 
  • Form Factor: LGX 
  • Temp Range: I-Temp 

Topologies

  • Central Office 
  • Headend 
  • Remote Site 
  • Cabinet 
  • Pedestal 

Deployment

  • Point to Point 
  • Linear Chain 
  • Collapsed/Diverse Ring 
TECHNICAL SPECS
ParameterUnitSpecification
NUMBER OF CHANNELSCH1 DWDM, WEST & EAST
OPERATING WAVELENGTHnm1520-1570
DWDM CHANNEL SPACINGGHz100
PASSBAND: EXPRESSnm1520-1570
PASSBAND: DWDM CHANNELSnmITU ± .11
ORDERING IFORMATION
VIEW ORDERING INFO
Part NumberDescription
PLO-L3DT-A101-LCLGX, 1 Channel DWDM OADM, ITU C20, 1561.42, 2% Monitor, LC-UPC
PLO-L3DT-A102-LCLGX, 1 Channel DWDM OADM, ITU C21, 1560.61, 2% Monitor, LC-UPC
PLO-L3DT-A103-LCLGX, 1 Channel DWDM OADM, ITU C22, 1559.79, 2% Monitor, LC-UPC
PLO-L3DT-A104-LCLGX, 1 Channel DWDM OADM, ITU C23, 1558.98, 2% Monitor, LC-UPC
PLO-L3DT-A105-LCLGX, 1 Channel DWDM OADM, ITU C24, 1558.17, 2% Monitor, LC-UPC
PLO-L3DT-A106-LCLGX, 1 Channel DWDM OADM, ITU C25, 1557.36, 2% Monitor, LC-UPC
PLO-L3DT-A107-LCLGX, 1 Channel DWDM OADM, ITU C26, 1556.55, 2% Monitor, LC-UPC
PLO-L3DT-A108-LCLGX, 1 Channel DWDM OADM, ITU C27, 1555.75, 2% Monitor, LC-UPC
PLO-L3DT-A109-LCLGX, 1 Channel DWDM OADM, ITU C28, 1554.94, 2% Monitor, LC-UPC
PLO-L3DT-A110-LCLGX, 1 Channel DWDM OADM, ITU C29, 1554.13, 2% Monitor, LC-UPC
PLO-L3DT-A112-LCLGX, 1 Channel DWDM OADM, ITU C30, 1553.33, 2% Monitor, LC-UPC
PLO-L3DT-A112-LCLGX, 1 Channel DWDM OADM, ITU C31, 1552.52, 2% Monitor, LC-UPC
PLO-L3DT-A113-LCLGX, 1 Channel DWDM OADM, ITU C32, 1551.72, 2% Monitor, LC-UPC
PLO-L3DT-A114-LCLGX, 1 Channel DWDM OADM, ITU-C33, 1550.92, 2% Monitor, LC-UPC
PLO-L3DT-A115-LCLGX, 1 Channel DWDM OADM, ITU C34, 1550.12, 2% Monitor, LC-UPC
PLO-L3DT-A116-LCLGX, 1 Channel DWDM OADM, ITU C35, 1549.32, 2% Monitor, LC-UPC
PLO-L3DT-A117-LCLGX, 1 Channel DWDM OADM, ITU C36, 1548.51, 2% Monitor, LC-UPC
PLO-L3DT-A118-LCLGX, 1 Channel DWDM OADM, ITU C37, 1547.72, 2% Monitor, LC-UPC
PLO-L3DT-A119-LCLGX, 1 Channel DWDM OADM, ITU C38, 1546.92, 2% Monitor, LC-UPC
PLO-L3DT-A120-LCLGX, 1 Channel DWDM OADM, ITU C39, 1546.12, 2% Monitor, LC-UPC
PLO-L3DT-A121-LCLGX, 1 Channel DWDM OADM, ITU C40, 1545.32, 2% Monitor, LC-UPC
PLO-L3DT-A122-LCLGX, 1 Channel DWDM OADM, ITU C41, 1544.53, 2% Monitor, LC-UPC
PLO-L3DT-A123-LCLGX, 1 Channel DWDM OADM, ITU C42, 1543.73, 2% Monitor, LC-UPC
PLO-L3DT-A124-LCLGX, 1 Channel DWDM OADM, ITU C43, 1542.94, 2% Monitor, LC-UPC
PLO-L3DT-A125-LCLGX, 1 Channel DWDM OADM, ITU C44, 1542.14, 2% Monitor, LC-UPC
PLO-L3DT-A126-LCLGX, 1 Channel DWDM OADM, ITU C45, 1541.35, 2% Monitor, LC-UPC
PLO-L3DT-A127-LCLGX, 1 Channel DWDM OADM, ITU C46, 1540.56, 2% Monitor, LC-UPC
PLO-L3DT-A128-LCLGX, 1 Channel DWDM OADM, ITU C47, 1539.77, 2% Monitor, LC-UPC
PLO-L3DT-A129-LCLGX, 1 Channel DWDM OADM, ITU C48, 1538.98, 2% Monitor, LC-UPC
PLO-L3DT-A130-LCLGX, 1 Channel DWDM OADM, ITU C49, 1538.19, 2% Monitor, LC-UPC
PLO-L3DT-A131-LCLGX, 1 Channel DWDM OADM, ITU C50, 1537.40, 2% Monitor, LC-UPC
PLO-L3DT-A132-LCLGX, 1 Channel DWDM OADM, ITU C51, 1536.61, 2% Monitor, LC-UPC
PLO-L3DT-A133-LCLGX, 1 Channel DWDM OADM, ITU C52, 1535.82, 2% Monitor, LC-UPC
PLO-L3DT-A134-LCLGX, 1 Channel DWDM OADM, ITU C53, 1535.04, 2% Monitor, LC-UPC
PLO-L3DT-A135-LCLGX, 1 Channel DWDM OADM, ITU C54, 1534.25, 2% Monitor, LC-UPC
PLO-L3DT-A136-LCLGX, 1 Channel DWDM OADM, ITU C55, 1533.47, 2% Monitor, LC-UPC
PLO-L3DT-A137-LCLGX, 1 Channel DWDM OADM, ITU C56, 1532.68, 2% Monitor, LC-UPC
PLO-L3DT-A138-LCLGX, 1 Channel DWDM OADM, ITU C57, 1531.90, 2% Monitor, LC-UPC
PLO-L3DT-A139-LCLGX, 1 Channel DWDM OADM, ITU C58, 1531.12, 2% Monitor, LC-UPC
PLO-L3DT-A140-LCLGX, 1 Channel DWDM OADM, ITU C59, 1530.33, 2% Monitor, LC-UPC