40-Channel DWDM Gaussian, 1RU Rackmount
Overview
The 40-channel DWDM Mux/Demux filter provides a solid capacity solution for modern fiber networks. This Rackmount filter uses ITU standard wavelengths that align with industry fixed and tunable transceivers. Utilizing 1 rack unit (1RU), and 100GHz channel spacing, this rack mounted filter provides a very economical capacity solution. The 40-channel Mux/Demux utilizes low loss and reliable Gaussian filters to help increase the optical power budget of your fiber network.
DWDM capacity solutions are passive and require no power, or configuration. DWDM filters are used to allow the combination (Multiplexing) and separation (Demultiplexing) of multiple wavelengths over single mode fiber and provide a high quality, low loss, fiber capacity solution.
Plugin Optics 40-Channel DWDM solutions support controlled environment deployments. Placing these filters allow you to deploy new high data rate circuits or recover existing fiber along a route, reducing or eliminating the need for new fiber builds all together.
Features
- Capacity Gain: 40 to 1
- Monitor Port: 2%
- 40 ITU Channels
- Low Loss Gaussian Filter
- Technology: DWDM
- Configuration: Mux/Demux
- Form Factor: 1 Rack Unit
Topologies
- Point to Point
- Linear Chain
- Collapsed/Diverse Ring
Deployment
- Central Office, Head End, Data Center, MDU
Parameter | Unit | Specification |
---|---|---|
NUMBER OF CHANNELS | CH | 40ch DWDM |
OPERATING WAVELENGTH | nm | 1260-1620 |
DWDM CHANNEL SPACING | GHz | 100 |
PASSBAND: MON PORT | nm | 1260-1570 |
PASSBAND: DWDM CHANNELS | nm | ITU ± .11 |
INSERTION LOSS | dB | <4.0 |
Part Number | Description |
---|---|
PLO-11DG-AAAA-LC | 1RU, 19-23 Inch, 40 Channel DWDM Mux-Demux, Gaussian, ITU CH 20-59, 1561.42 - 1530.33, 2% Monitor, LC-UPC |
8-Channel DWDM +1310nm MUX/DMX, LGX
Overview
The 8-channel DWDM + 1310nm filter and Expansion port provides a solid capacity solution for modern fiber networks. This LGX module combines 8 ITU standard DWDM wavelengths and a wideband 1310nm port to allow the overlay of legacy 1310nm circuits or the next evolution of 100G circuits. The included Expansion port provides additional growth up to 40 DWDM channels without interrupting the initially deployed circuits.
DWDM capacity solutions are passive and require no power, or configuration. DWDM filters are used to allow the combination (Multiplexing) and separation (Demultiplexing) of multiple wavelengths over single mode fiber and provide a high quality, low loss, fiber capacity solution.
Plugin Optics LGX mounting solutions support controlled environment and I-Temp deployments.
Features
- 8 Channel DWDM
- Configuration: Mux/Dmx
- 5 Variants: ITU Ch 20-59
- 2% Monitor Port
- Form Factor: LGX
- Temp Range: I-Temp
Topologies
- Central Office
- Headend
- Remote Site
- Cabinet
- Pedestal
Deployment
- Point to Point
- Linear Chain
- Collapsed/Diverse Ring
Parameter | Unit | Specification |
---|---|---|
NUMBER OF CHANNELS | CH | 8 DWDM, +1310nm, EXPANSION PORT |
OPERATING WAVELENGTH | nm | 1260-1360, 1520-1570 |
DWDM CHANNEL SPACING | GHz | 100 |
PASSBAND: 1310NM PORT | nm | 1260-1360 |
PASSBAND: EXPANSION PORT | nm | 1520-1570 |
PASSBAND: DWDM CHANNELS | nm | ITU ± .11 |
INSERTION LOSS | dB | 1310nm < 1.4, EXP< 3.2, COM-DWDM <3.4 |
Part Number | Description |
---|---|
PLO-L2DT-B9C1-LC | LGX, 8 CHANNEL DWDM +1310 +EXP, MUX-DEMUX, ITIU C21-C27, 1561.42 - 1555.75, 2% MONITOR, LC-UPC |
PLO-L2DT-B9C2-LC | LGX, 8 CHANNEL DWDM +1310 +EXP, MUX-DEMUX, ITU C28-C35, 1554.94 - 1549.32, 2% MONITOR, LC-UPC |
PLO-L2DT-B9C3-LC | LGX, 8 CHANNEL DWDM +1310 +EXP, MUX-DEMUX, ITU C36-C43, 1548.51 - 1542.94, 2% MONITOR, LC-UPC |
PLO-L2DT-B9C4-LC | LGX, 8 CHANNEL DWDM +1310 +EXP, MUX-DEMUX, ITU C44-51, 1542.14 - 1536.61, 2% MONITOR, LC-UPC |
PLO-L2DT-B9C5-LC | LGX, 8 CHANNEL DWDM +1310 +EXP, MUX-DEMUX, ITU C52-C59, 1535.82 - 1530.33, 2% MONITOR, LC-UPC |
4-Channel DWDM OADM, LGX
Overview
DWDM Optical Add/Drop Multiplexers (OADM) allow for midspan access of DWDM channels along a single mode fiber route. 4-channel DWDM OADMs are commonly used at sites along a fiber route carrying 8 to 40+ DWDM channels and allow access to 4 channels while expressing the remaining channels through the site.
Plugin Optics DWDM OADM filter solutions are passive and require no power, or configuration. OADM filters are used to allow adding and dropping of DWDM wavelengths, West and East, along a single mode fiber route and provide a high quality, low loss, fiber capacity solution.
Plugin Optics LGX mounting solutions support controlled environment and I-Temp deployments.
Features
- 4 Channel DWDM
- Configuration: OADM
- 10 Variants: ITU Ch 20-59
- 2% Monitor Port
- Form Factor: LGX
- Temp Range: I-Temp
Topologies
- Central Office
- Headend
- Remote Site
- Cabinet
- Pedestal
Deployment
- Point to Point
- Linear Chain
- Collapsed/Diverse Ring
Parameter | Unit | Specification |
---|---|---|
NUMBER OF CHANNELS | CH | 4 DWDM, WEST & EAST |
OPERATING WAVELENGTH | nm | 1520-1570 |
DWDM CHANNEL SPACING | GHz | 100 |
PASSBAND: EXPRESS | nm | 1520-1570 |
PASSBAND: DWDM CHANNELS | nm | ITU ± .11 |
INSERTION LOSS | dB | EXP< 3.5, COM-DWDM <3.7 |
Part Number | Description |
---|---|
PLO-L3DT-A4D1-LC | LGX, 4 CHANNEL DWDM OADM, ITU C20-C23, 1561.42, 1560.61, 1559.79, 1558.98, 2% MONITOR, LC-UPC |
PLO-L3DT-A4D2-LC | LGX, 4 CHANNEL DWDM OADM, ITU C24-C27, 1558.17, 1557.36, 1556.55, 1555.75, 2% MONITOR, LC-UPC |
PLO-L3DT-A4D3-LC | LGX, 4 CHANNEL DWDM OADM, ITU C28-C31, 1554.94, 1554.13, 1553.33, 1552.52, 2% MONITOR, LC-UPC |
PLO-L3DT-A4D4-LC | LGX, 4 CHANNEL DWDM OADM, ITU C32-C35, 1551.72, 1550.92, 1550.12, 1549.32, 2% MONITOR, LC-UPC |
PLO-L3DT-A4D5-LC | LGX, 4 CHANNEL DWDM OADM, ITU C36-C39, 1548.51, 1547.72, 1546.92, 1546.12, 2% MONITOR, LC-UPC |
PLO-L3DT-A4D6-LC | LGX, 4 CHANNEL DWDM OADM, ITU C40-C43, 1545.32, 1544.53, 1543.73, 1542.94, 2% MONITOR, LC-UPC |
PLO-L3DT-A4D7-LC | LGX, 4 CHANNEL DWDM OADM, ITU C44-C47, 1542.14, 1541.35, 1540.56, 1539.77, 2% MONITOR, LC-UPC |
PLO-L3DT-A4D8-LC | LGX, 4 CHANNEL DWDM OADM, ITU C48-C51, 1538.98, 1538.19, 1537.40, 1536.61, 2% MONITOR, LC-UPC |
PLO-L3DT-A4D9-LC | LGX, 4 CHANNEL DWDM OADM, ITU C52-C55, 1535.82, 1535.04, 1534.25, 1533.47, 2% MONITOR, LC-UPC |
PLO-L3DT-A4D0-LC | LGX, 4 CHANNEL DWDM OADM, ITU C56-C59, 1532.68, 1531.90, 1531.12, 1530.33, 2% MONITOR, LC-UPC |
2-Channel DWDM OADM, LGX
Overview
DWDM Optical Add/Drop Multiplexers (OADM) allow for midspan access of DWDM channels along a single mode fiber route. 2-channel DWDM OADMs are commonly used at sites along a fiber route carrying 8 to 40+ DWDM channels and allow access to 2 channels while expressing the remaining channels through the site.
Plugin Optics DWDM OADM filter solutions are passive and require no power, or configuration. OADM filters are used to allow adding and dropping of DWDM wavelengths, West and East, along a single mode fiber route and provide a high quality, low loss, fiber capacity solution.
Plugin Optics LGX mounting solutions support controlled environment and I-Temp deployments.
Features
- 2 Channel DWDM
- Configuration: OADM
- 20 Variants: ITU Ch 20-59
- 2% Monitor Port
- Form Factor: LGX
- Temp Range: I-Temp
Topologies
- Central Office
- Headend
- Remote Site
- Cabinet
- Pedestal
Deployment
- Point to Point
- Linear Chain
- Collapsed/Diverse Ring
Parameter | Unit | Specification |
---|---|---|
NUMBER OF CHANNELS | CH | 2 DWDM, WEST & EAST |
OPERATING WAVELENGTH | nm | 1520-1570 |
DWDM CHANNEL SPACING | GHz | 100 |
PASSBAND: EXPRESS | nm | 1520-1570 |
PASSBAND: DWDM CHANNELS | nm | ITU ± .11 |
INSERTION LOSS | dB | EXP< 2.2, COM-DWDM <1.9 |
Part Number | Description |
---|---|
PLO-L3DT-A2E1-LC | LGX, 2 CHANNEL DWDM OADM, ITU C20-C21, 1561.42, 1560.61, 2% MONITOR, LC-UPC |
PLO-L3DT-A2E2-LC | LGX, 2 CHANNEL DWDM OADM, ITU C22-C23, 1559.79, 1558.98, 2% MONITOR, LC-UPC |
PLO-L3DT-A2E3-LC | LGX, 2 CHANNEL DWDM OADM, ITU C24-C25, 1558.17, 1557.36, 2% MONITOR, LC-UPC |
PLO-L3DT-A2E4-LC | LGX, 2 CHANNEL DWDM OADM, ITU C26-C27, 1556.55, 1555.75, 2% MONITOR, LC-UPC |
PLO-L3DT-A2E5-LC | LGX, 2 CHANNEL DWDM OADM, ITU C28-C39, 1554.94, 1554.13, 2% MONITOR, LC-UPC |
PLO-L3DT-A2E6-LC | LGX, 2 CHANNEL DWDM OADM, ITU C30-C31, 1553.33, 1552.52, 2% MONITOR, LC-UPC |
PLO-L3DT-A2E7-LC | LGX, 2 CHANNEL DWDM OADM, ITU C32-C33, 1551.72, 1550.92, 2% MONITOR, LC-UPC |
PLO-L3DT-A2E8-LC | LGX, 2 CHANNEL DWDM OADM, ITU C34-C35, 1550.12, 1549.32, 2% MONITOR, LC-UPC |
PLO-L3DT-A2E9-LC | LGX, 2 CHANNEL DWDM OADM, ITU C36-C37, 1548.51, 1547.72, 2% MONITOR, LC-UPC |
PLO-L3DT-A2E0-LC | LGX, 2 CHANNEL DWDM OADM, ITU C38-C39, 1546.92, 1546.12, 2% MONITOR, LC-UPC |
PLO-L3DT-A2EA-LC | LGX, 2 CHANNEL DWDM OADM, ITU C40-C41, 1545.32, 1544.53, 2% MONITOR, LC-UPC |
PLO-L3DT-A2EB-LC | LGX, 2 CHANNEL DWDM OADM, ITU C42-C43, 1543.73, 1542.94, 2% MONITOR, LC-UPC |
PLO-L3DT-A2EC-LC | LGX, 2 CHANNEL DWDM OADM, ITU C44-C45, 1542.14, 1541.35, 2% MONITOR, LC-UPC |
PLO-L3DT-A2ED-LC | LGX, 2 CHANNEL DWDM OADM, ITU C46-C47, 1540.56, 1539.77, 2% MONITOR, LC-UPC |
PLO-L3DT-A2EE-LC | LGX, 2 CHANNEL DWDM OADM, ITU C48-C49, 1538.98, 1538.19, 2% MONITOR, LC-UPC |
PLO-L3DT-A2EF-LC | LGX, 2 CHANNEL DWDM OADM, ITU C50-C51, 1537.40, 1536.61, 2% MONITOR, LC-UPC |
PLO-L3DT-A2EG-LC | LGX, 2 CHANNEL DWDM OADM, ITU C52-C53, 1535.82, 1535.04, 2% MONITOR, LC-UPC |
PLO-L3DT-A2EH-LC | LGX, 2 CHANNEL DWDM OADM, ITU C54-C55, 1534.25, 1533.47, 2% MONITOR, LC-UPC |
PLO-L3DT-A2EJ-LC | LGX, 2 CHANNEL DWDM OADM, ITU C56-C57, 1532.68, 1531.90, 2% MONITOR, LC-UPC |
PLO-L3DT-A2EK-LC | LGX, 2 CHANNEL DWDM OADM, ITU C58-C59, 1531.12, 1530.33, 2% MONITOR, LC-UPC |
1-Channel DWDM OADM, LGX
Overview
DWDM Optical Add/Drop Multiplexers (OADM) allow for midspan access of DWDM channels along a single mode fiber route. 1-channel DWDM OADMs are commonly used at sites along a fiber route carrying 8 to 40+ DWDM channels and allow access to 1 channel while expressing the remaining channels through the site.
Plugin Optics DWDM OADM filter solutions are passive and require no power, or configuration. OADM filters are used to allow adding and dropping of DWDM wavelengths, West and East, along a single mode fiber route and provide a high quality, low loss, fiber capacity solution.
Plugin Optics LGX mounting solutions support controlled environment and I-Temp deployments.
Features
- 1 Channel DWDM
- Configuration: OADM
- 40 Variants: ITU Ch 20-59
- 2% Monitor Port
- Form Factor: LGX
- Temp Range: I-Temp
Topologies
- Central Office
- Headend
- Remote Site
- Cabinet
- Pedestal
Deployment
- Point to Point
- Linear Chain
- Collapsed/Diverse Ring
Parameter | Unit | Specification |
---|---|---|
NUMBER OF CHANNELS | CH | 1 DWDM, WEST & EAST |
OPERATING WAVELENGTH | nm | 1520-1570 |
DWDM CHANNEL SPACING | GHz | 100 |
PASSBAND: EXPRESS | nm | 1520-1570 |
PASSBAND: DWDM CHANNELS | nm | ITU ± .11 |
Part Number | Description |
---|---|
PLO-L3DT-A101-LC | LGX, 1 Channel DWDM OADM, ITU C20, 1561.42, 2% Monitor, LC-UPC |
PLO-L3DT-A102-LC | LGX, 1 Channel DWDM OADM, ITU C21, 1560.61, 2% Monitor, LC-UPC |
PLO-L3DT-A103-LC | LGX, 1 Channel DWDM OADM, ITU C22, 1559.79, 2% Monitor, LC-UPC |
PLO-L3DT-A104-LC | LGX, 1 Channel DWDM OADM, ITU C23, 1558.98, 2% Monitor, LC-UPC |
PLO-L3DT-A105-LC | LGX, 1 Channel DWDM OADM, ITU C24, 1558.17, 2% Monitor, LC-UPC |
PLO-L3DT-A106-LC | LGX, 1 Channel DWDM OADM, ITU C25, 1557.36, 2% Monitor, LC-UPC |
PLO-L3DT-A107-LC | LGX, 1 Channel DWDM OADM, ITU C26, 1556.55, 2% Monitor, LC-UPC |
PLO-L3DT-A108-LC | LGX, 1 Channel DWDM OADM, ITU C27, 1555.75, 2% Monitor, LC-UPC |
PLO-L3DT-A109-LC | LGX, 1 Channel DWDM OADM, ITU C28, 1554.94, 2% Monitor, LC-UPC |
PLO-L3DT-A110-LC | LGX, 1 Channel DWDM OADM, ITU C29, 1554.13, 2% Monitor, LC-UPC |
PLO-L3DT-A112-LC | LGX, 1 Channel DWDM OADM, ITU C30, 1553.33, 2% Monitor, LC-UPC |
PLO-L3DT-A112-LC | LGX, 1 Channel DWDM OADM, ITU C31, 1552.52, 2% Monitor, LC-UPC |
PLO-L3DT-A113-LC | LGX, 1 Channel DWDM OADM, ITU C32, 1551.72, 2% Monitor, LC-UPC |
PLO-L3DT-A114-LC | LGX, 1 Channel DWDM OADM, ITU-C33, 1550.92, 2% Monitor, LC-UPC |
PLO-L3DT-A115-LC | LGX, 1 Channel DWDM OADM, ITU C34, 1550.12, 2% Monitor, LC-UPC |
PLO-L3DT-A116-LC | LGX, 1 Channel DWDM OADM, ITU C35, 1549.32, 2% Monitor, LC-UPC |
PLO-L3DT-A117-LC | LGX, 1 Channel DWDM OADM, ITU C36, 1548.51, 2% Monitor, LC-UPC |
PLO-L3DT-A118-LC | LGX, 1 Channel DWDM OADM, ITU C37, 1547.72, 2% Monitor, LC-UPC |
PLO-L3DT-A119-LC | LGX, 1 Channel DWDM OADM, ITU C38, 1546.92, 2% Monitor, LC-UPC |
PLO-L3DT-A120-LC | LGX, 1 Channel DWDM OADM, ITU C39, 1546.12, 2% Monitor, LC-UPC |
PLO-L3DT-A121-LC | LGX, 1 Channel DWDM OADM, ITU C40, 1545.32, 2% Monitor, LC-UPC |
PLO-L3DT-A122-LC | LGX, 1 Channel DWDM OADM, ITU C41, 1544.53, 2% Monitor, LC-UPC |
PLO-L3DT-A123-LC | LGX, 1 Channel DWDM OADM, ITU C42, 1543.73, 2% Monitor, LC-UPC |
PLO-L3DT-A124-LC | LGX, 1 Channel DWDM OADM, ITU C43, 1542.94, 2% Monitor, LC-UPC |
PLO-L3DT-A125-LC | LGX, 1 Channel DWDM OADM, ITU C44, 1542.14, 2% Monitor, LC-UPC |
PLO-L3DT-A126-LC | LGX, 1 Channel DWDM OADM, ITU C45, 1541.35, 2% Monitor, LC-UPC |
PLO-L3DT-A127-LC | LGX, 1 Channel DWDM OADM, ITU C46, 1540.56, 2% Monitor, LC-UPC |
PLO-L3DT-A128-LC | LGX, 1 Channel DWDM OADM, ITU C47, 1539.77, 2% Monitor, LC-UPC |
PLO-L3DT-A129-LC | LGX, 1 Channel DWDM OADM, ITU C48, 1538.98, 2% Monitor, LC-UPC |
PLO-L3DT-A130-LC | LGX, 1 Channel DWDM OADM, ITU C49, 1538.19, 2% Monitor, LC-UPC |
PLO-L3DT-A131-LC | LGX, 1 Channel DWDM OADM, ITU C50, 1537.40, 2% Monitor, LC-UPC |
PLO-L3DT-A132-LC | LGX, 1 Channel DWDM OADM, ITU C51, 1536.61, 2% Monitor, LC-UPC |
PLO-L3DT-A133-LC | LGX, 1 Channel DWDM OADM, ITU C52, 1535.82, 2% Monitor, LC-UPC |
PLO-L3DT-A134-LC | LGX, 1 Channel DWDM OADM, ITU C53, 1535.04, 2% Monitor, LC-UPC |
PLO-L3DT-A135-LC | LGX, 1 Channel DWDM OADM, ITU C54, 1534.25, 2% Monitor, LC-UPC |
PLO-L3DT-A136-LC | LGX, 1 Channel DWDM OADM, ITU C55, 1533.47, 2% Monitor, LC-UPC |
PLO-L3DT-A137-LC | LGX, 1 Channel DWDM OADM, ITU C56, 1532.68, 2% Monitor, LC-UPC |
PLO-L3DT-A138-LC | LGX, 1 Channel DWDM OADM, ITU C57, 1531.90, 2% Monitor, LC-UPC |
PLO-L3DT-A139-LC | LGX, 1 Channel DWDM OADM, ITU C58, 1531.12, 2% Monitor, LC-UPC |
PLO-L3DT-A140-LC | LGX, 1 Channel DWDM OADM, ITU C59, 1530.33, 2% Monitor, LC-UPC |